Rosemount
Temperature Transmitter
Temperature measurement assembly with Rosemount X-well Technology (option code PT)
Dual and single sensor input capabilities
3144P-D1A2K5M5B4T1Q4C4U1WR3
D1 : Field Mount, Dual-Compartment Housing | Aluminum | ½-14 NPT
A : 4-20 mA with digital signal based on HART protocol
2 : Dual Sensor
K5 : FM IS, nonincendive & explosionproof combo (includes standard IS and FISCO for fieldbus units)
B4 : "U" Mounting Bracket for 2-inch pipe mounting - All SST
M5 : LCD Display
T1 : Integral Transient Protector
C4 : 5-Point Calibration (Requires the Q4 option code to generate a Calibration Certificate)
Q4 : Calibration Certificate (3-Point Calibration)
U1 : Hot Backup Enabled - Sensor Drift Alert Off