Deltabar S FMD77
FMD77-AAC7F4H1NRAA+Z1
Approval: A = Non-hazardous area
Output; Operating: A = 4-20mA HART; extern + LCD
Housing; Cover Sealing; Cable Entry: C = T14 Alu IP66/67 NEMA6P; EPDM; NPT1/2 thread, T14 = side cover
Nominal Range; Cell Material; PN: 7F = 500mbar/50kPa/7.5psi; 316L; 160bar/ 16MPa/2400psi
Calibration; Unit: 4 = Nominal range; inH2O/ftH2O
Membrane Material: H = 316L, high + low pressure side
Process Connection; LP Side; Seal: 1 = LP diaphragm seal with capillary; welded
Process Connection, HP/HP+LP: N = NPS 2" Cl.150 RF, 316/316L flange ASME B16.5
Fill Fluid: R = ..... ft capillary, silicone oil, LP-side
Additional Option 1: A = Not selected
Additional Option 2: A = Not selected
Marking: Z1 = Tagging (TAG), see additional spec.